{"product_id":"canheat-8d-high-capacity","title":"CANHEAT 8D Dual-Output System","description":"\u003cp\u003eHigh-capacity heat for large, 24\/7 operations — heating multi-tent setups with dual output and external fuel supply.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDual outlet design allows for split-zone heating\u003c\/li\u003e\n\u003cli\u003e8 kW-class heater supports command centres and large tents\u003c\/li\u003e\n\u003cli\u003eExtended runtime and rapid deployment in 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHigh capacity for large operations\u003c\/h3\u003e\n\u003cp\u003eThe 8D configuration uses an 8 kW-class heater core to support larger tents, command centres and logistics hubs where 4 kW systems are undersized — extending the CanHeat platform into sustained base-level operations rather than small team shelters.\u003c\/p\u003e\n\n\u003ch3\u003eDual output heating\u003c\/h3\u003e\n\u003cp\u003eThe 8D's dual outlet design lets one heater serve two tents or zones, or split airflow between a main shelter and spaces like vestibules or storage areas. Ducting allows heat distribution to be tuned without adding another heater core.\u003c\/p\u003e\n\n\u003ch3\u003eExtended range controller\u003c\/h3\u003e\n\u003cp\u003eA 10 ft control lead lets crew manage output from inside while the heater remains outside, maintaining separation from personnel and sensitive equipment while simplifying checks during long rotations in extreme cold.\u003c\/p\u003e\n\n\u003ch3\u003eExternal fuel supply\u003c\/h3\u003e\n\u003cp\u003eCompatible with external bulk fuel tanks, the 8D enables extended, low-intervention 24\/7 operation for command, medical or support use — leveraging diesel or aviation-grade fuel logistics to heat large shelters over long deployments.\u003c\/p\u003e\n\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeater Core (CANHEAT 8D)\u003c\/li\u003e\n\u003cli\u003eDual-Control Module (CANHEAT 8D-CM)\u003c\/li\u003e\n\u003cli\u003eMIL-spec Control Cable (10 ft)\u003c\/li\u003e\n\u003cli\u003eMIL-spec Power Cable (DC, 10 ft)\u003c\/li\u003e\n\u003cli\u003eMIL-spec Power Cable (AC, 10 ft)\u003c\/li\u003e\n\u003cli\u003e2x High-temp Air Hose (Ø 4.0 in, 10 ft)\u003c\/li\u003e\n\u003cli\u003eReturn Air Hose (Ø 3.0 in, 10 ft)\u003c\/li\u003e\n\u003cli\u003eExternal Fuel Adapter (fits Scepter 20 L MIL-spec container)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 13,600 BTU\/h (2x 4.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 98 ft³\/min (2x 168 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC \/ 100 – 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 10.0 – 57.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiesel, kerosene, JP-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 0.12 – 0.5 l\/h (2x 0.03 – 0.13 gal\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (heater core)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75.0 lb (33.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (heater core)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.8 × 25.6 × 25.2 in (630 × 650 × 340 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSafety and certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully separated combustion and cabin air circuits\u003c\/li\u003e\n\u003cli\u003eSealed combustion system with external exhaust\u003c\/li\u003e\n\u003cli\u003eOverheat protection with automatic shutdown\u003c\/li\u003e\n\u003cli\u003eMIL-spec connectors and shielded wiring, EMI\/EMC tested\u003c\/li\u003e\n\u003cli\u003eCE certified (EMC \u0026amp; LVD) by Intertek\u003c\/li\u003e\n\u003cli\u003eNATO- and NCAGE-coded — NSN available for qualified systems\u003c\/li\u003e\n\u003cli\u003eEngineered and built in Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e tactical shelters · tents · command posts · medical stations · guard posts\u003c\/p\u003e","brand":"CanHeat Tactical","offers":[{"title":"Default Title","offer_id":46158203748543,"sku":"CANHEAT-8D","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9840\/3519\/files\/Captured_ecran_7-9-2026_163127_canheat.ca.jpg?v=1788813124","url":"https:\/\/fairdcanada.com\/es\/products\/canheat-8d-high-capacity","provider":"FairD Canada","version":"1.0","type":"link"}